Renovation Stair Nosing for Existing Facilities

View from aboveView from above
View from above
View from the side
Construction drawing - Side
Construction drawing - Stair step

Item No: 90.US0333-B

Contact EverGlow


Toll Free:   (1) 866-744-4706
Telephone: (1) 704-841-2580
Email Us:  This email address is being protected from spambots. You need JavaScript enabled to view it.


We take orders over the phone. We accept all major credit/debit cards. Click here for Terms and Conditions.

Preloader

High quality photoluminescent (glow-in-the dark) slip resistant renovation stair nosing that meets the requirements of NYC Local Law 26, current NYC building and fire codes, current IBC & IFC model codes and all local building & fire codes across the United States. These nosings are used for exit path markings, steps and leading edge of landings when finding pathways in the dark is a necessity. The use of a heat treated corrosion resistant aluminum substrate with a slip resistant aluminum oxide surface assures long tread life under heavy pedestrian traffic. These safety surfaces have easy maintenance features and ensure the greatest protection from falls and injuries.

Features:

  • Extruded Aluminum base type 6063-T6
  • Lengths to order - up to 8 feet
  • Bright, long lasting photoluminescent marker
  • Smooth easy to clean surface
  • Clean architectural lines
  • High content of aluminum oxide slip resistant surface
  • Meets or exceeds NYC RS 6-1 and current NYC building and fire codes
  • Meets or exceeds current IBC & IFC (model) codes, and all current local building and fire codes across the US
  • Meets or exceeds NFPA 101 (2012 edition) and all current editions of NFPA 101 - Life Safety Code
  • Meets or exceeds the luminance requirements of ASTM E2072 and E2073
  • Meets or exceeds the luminance requirements of UL1994 and UL S572 (Canada)
  • Coefficient of friction (slip resistance) meets or exceeds OSHA standard 1910.22, ASTM standards and military specifications

Specifications:

  • 90.US0333-B, Renovation Stair Nosing for Existing Facilities for interior and exterior stairs.
  • Type of Anchor shall be specified.
  • Compliant with all requirements of New York City local law 26 (2004) RS 6-1 and RS 6-1A, viz., flammability (ASTM D635-2003), toxicity (SMP 800C), washability (ASTM 4828-1994), radioactivity (ASTM D 3684-2004) and brightness (ISO 17398-2004).
  • Meets or exceeds current NYC building and fire codes.
  • Meets or exceeds current IBC & IFC (model) codes, and all current local building and fire codes across the US.
  • Meets or exceeds NFPA 101 (2012 edition) and all current editions of NFPA 101 - Life Safety Code.
  • Meets or exceeds the luminance requirements of ASTM E2072 and E2073.
  • Meets or exceeds the luminance requirements of UL1994 and UL S572 (Canada).
  • Nosing base shall be type 6063-T5 extruded aluminum.
  • Photoluminescent front groove to be filled with 16% minimum resilient type epoxy filler for improved clean ability.
  • Photoluminescent epoxy filler (free of hazardous and radioactive substances) shall extend uniformly throughout the filler.
  • Nosings shall terminate not more than 2" from ends of steps.
  • Coefficient of friction (slip resistance) meets or exceeds OSHA standard 1910.22, ASTM standards and military specifications.
  • Smooth photoluminescent glow area with excellent cleanability. Highest possible score of 10 on the soil expansion index (ASTM D4829) test.

90.US0333-B:  EverGlow Renovation Stair Nosing for Existing Facilities - Product Data Sheet

Installation Instructions
Cleaning Instructions
Maintenance Instructions